13 Generic clinical admin spaces: Offices

Office/meeting room

13.3 Lamp repeat calls for controlled drug cupboards (if used) and a key cupboard may be located here.

Room description and layout

13.4 A small safe, an alarm panel (see ‘Bedhead services’) and cube lockers for the storage of staff personal belongings may also be provided.

13.1 An office/meeting room is intended as a multipurpose office within a clinical environment for handover meetings and technical reviews.

13.2 The room layout provided (see Figure 119) includes two workstations and a table and chairs for informal meetings/handovers in an enclosed office.

13.5 A printer may be provided in each office if a shared printer is not available nearby. However, consideration must be given to the negative sustainability issues relating to the provision of many small local printers.

Figure 119 Space requirements for enclosed office, two workstations, table and chairs

Engineering services outlet zone

Desk or desktop

Filing cabinet

Desk or desktop

Noticeboard

Noticeboard

Engineering services outlet zone

Engineering services outlet zone

Mobile under-desk storage

Mobile under-desk storage

Office zone

Stacking chairs

Chair Chair

Table

Meeting zone

Chair

Chair

[HBN 00-03 – PDF page 154]

13 Generic clinical admin spaces: Offices

Ergonomic drawings

Administration workstation

13.8 Desks should include wire management and equipment should be able to be plugged in at desk height. Task lighting should be considered.

13.6 This ergonomic drawing (see Figure 120) shows the space requirements for an administration workstation.

13.9 The 900 mm space required to withdraw a chair from the desk will increase to 1000 mm for heavy upholstered chairs.

13.7 Office furniture should comply with BS EN 1335- 1.

13.10 Where there is frequent passing behind a desk, the preferred 1500 mm space should be provided. This will also allow for wheelchair access.

Figure 120 Space requirements for an administration workstation

Privacy screen

Minimum 1500 required for wheelchair access

1500 (1200) to obstruction

ambulant passing

Space to sit at desk/approx depth of storage unit

Noticeboard

Mobile under-desk storage

Approximate

width of mobile

storage unit

1400 (1200) – see notes

Filing cabinet or bookcase

Space to withdraw chair from desk

Space for ambulant passing when chair withdrawn

[HBN 00-03 – PDF page 155]

Working at a desk/table

13.13 The space requirement for a wheelchair user is based on a standard wheelchair.

13.11 This ergonomic drawing (see Figure 121) illustrates the space requirements for working at a desk/table.

13.14 The working zone on the desk/table is 700 mm wide by 500 mm deep. This may be compromised if two users sit at 90 degrees to one another at the corner of the desk/table.

13.12 The chair shown is a standard stacking chair. Where larger chairs are used, the space should be increased by an additional 100 mm in each direction.

Figure 121 Space requirements for working at a desk/table

Space for withdrawal of chair from table

Clearance for knees and feet

Space for chair

Approx working zone at table

chair

Clear space

under table

Space for sitting at

table, 600 min is

for bench seating

Space for withdrawal of independent wheelchair

Clear space to side

for independent

wheelchair access

ambulant passing

Approx working zone at table

wheelchair

user at table

Space under table

wheelchair close to table

ambulant passing

[HBN 00-03 – PDF page 156]

13 Generic clinical admin spaces: Offices

Office: 1-person

Room description and layout

13.17 A printer may be provided in each office if a shared printer is not available nearby. However, consideration must be given to the negative sustainability issues relating to the provision of many small local printers.

13.15 Single-person offices (see Figure 122) should only be provided where full-time access to workstations and constant privacy are required.

13.16 Offices may be used for discussions and informal interviews as well as clinical administration tasks.

13.18 If the room is used for clinical control, the lamp repeat calls for controlled drugs cupboards (if used) and a key cupboard will be required. A small safe and an alarm panel (see ‘Bedhead services’) may also be provided.

Figure 122 Space requirements for a single-person office

Engineering services outlet zone

Desk Filing cabinet or bookcase

Engineering services outlet zone

Mobile under-desk storage

Visitors’ chair

Visitors’ chair

Filing cabinet or bookcase

[HBN 00-03 – PDF page 157]

Ergonomic drawings

Administration workstation

13.21 Desks should include wire management and equipment should be able to be plugged in at desk height. Task lighting should be considered.

13.19 This ergonomic drawing (see Figure 123) shows the space requirements for an administration workstation.

13.22 The 900 mm space required to withdraw a chair from the desk will increase to 1000 mm for heavy upholstered chairs.

13.20 Office furniture should comply with BS EN 1335- 1.

13.23 Where there is frequent passing behind a desk, the preferred 1500 mm space should be provided. This will also allow for wheelchair access.

Figure 123 Space requirements for an administration workstation

Privacy screen

Minimum 1500 required for wheelchair access

1500 (1200) to obstruction

ambulant passing

Space to sit at desk/approx depth of storage unit

Noticeboard

Mobile under-desk storage

Approximate

width of mobile

storage unit

1400 (1200) – see notes

Filing cabinet or bookcase

Space to withdraw chair from desk

Space for ambulant passing when chair withdrawn

[HBN 00-03 – PDF page 158]

13 Generic clinical admin spaces: Offices

Office: 2-person

Room description and layout

13.25 A printer may be provided in each office if a shared printer is not available nearby. However, consideration must be given to the negative sustainability issues relating to the provision of many small local printers.

13.24 Offices may be used for discussions and informal interviews as well as clinical administration tasks.

Figure 124 Space requirements for a two-person office

Engineering services outlet zone

Visitor’s chair

Visitor’s chair

Filing cabinet or mobile storage

Filing cabinet or bookcase

Engineering services outlet zone

Mobile under-desk storage

Noticeboard

Noticeboard

Mobile under-desk storage

Filing cabinet or mobile storage

Engineering services outlet zone

Engineering services outlet zone

[HBN 00-03 – PDF page 159]

Health Building Note 00-03 – Clinical, clinical support and specialist spaces

Ergonomic drawings

Administration workstation

13.28 Desks should include wire management and equipment should be able to be plugged in at desk height. Task lighting should be considered.

13.26 This ergonomic drawing (see Figure 125) shows the space requirements for an administration workstation.

13.29 The 900 mm space required to withdraw a chair from the desk will increase to 1000 mm for heavy upholstered chairs.

13.27 Office furniture should comply with BS EN 1335- 1.

13.30 Where there is frequent passing behind a desk, the preferred 1500 mm space should be provided. This will also allow for wheelchair access.

Figure 125 Space requirements for an administration workstation

Privacy screen

Minimum 1500 required for wheelchair access

1500 (1200) to obstruction

ambulant passing

Space to sit at desk/approx depth of storage unit

Noticeboard

Mobile under-desk storage

Approximate

width of mobile

storage unit

1400 (1200) – see notes

Filing cabinet or bookcase

Space to withdraw chair from desk

Space for ambulant passing when chair withdrawn