[HBN 00-03 – PDF page 145]

Breakout space

Room description and layout

12.33 In open-plan admin areas, they provide extra capacity for workspace should all the shared workstations be occupied. Consideration should be given to providing power and data sockets/ outlets for a laptop and a telephone point.

12.31 Breakout spaces are intended to provide for ad hoc social interaction and/or discussions and may be used in either administration areas for staff or within clinical areas for patients or staff.

12.34 The room layout provided (see Figure 112) shows a breakout space for use within an administration area.

12.35 Breakout spaces may be located alongside the shared workstations they serve (as shown) or combined with other breakout spaces into a central resource for more flexibility in use.

12.32 The choice of furniture will depend upon the location and function of the space (for example within staff admin areas, chairs and a table for basic work functions, for patient use, easy chairs and a coffee table).

Figure 112 Space requirements for a breakout space within an administration area

approx 2300

approx 2700

[HBN 00-03 – PDF page 146]

12 Generic clinical admin spaces: Open-plan admin areas

Ergonomic drawings

Space to sit on an easy chair

12.37 When seats are pushed together in rows, the average seat width is 600–650 mm for seats without arms and 750 mm for seats with arms.

12.36 These ergonomic drawings (see Figure 113) show the space requirements for a person to sit on an easy chair.

Figure 113 Space requirements to sit on an easy chair

Preferred location of table

extended legs

easy chair

Clearance between

chair and table

for access

Space for seating

ambulant passing

Restricted leg space to allow person to pass

[HBN 00-03 – PDF page 147]

Working at a desk/table

12.40 The space requirement for a wheelchair user is based on a standard wheelchair.

12.38 This ergonomic drawing (see Figure 114) illustrates the space requirements for working at a desk/table.

12.41 The working zone on the desk/table is 700 mm wide by 500 mm deep. This may be compromised if two users sit at 90 degrees to one another at the corner of the desk/table.

12.39 The chair shown is a standard stacking chair. Where larger chairs are used, the space should be increased by an additional 100 mm in each direction.

Figure 114 Space requirements for working at a desk/table

Space for withdrawal of chair from table

Clearance for knees and feet

Space for chair

Approx working zone at table

chair

Clear space

under table

Space for sitting at

table, 600 min is

for bench seating

Space for withdrawal of independent wheelchair

Clear space to side

for independent

wheelchair access

ambulant passing

Approx working zone at table

wheelchair

user at table

Space under table

wheelchair close to table

ambulant passing

[HBN 00-03 – PDF page 148]

12 Generic clinical admin spaces: Open-plan admin areas

Quiet workspace

12.43 The room has been sized to discourage users from feeling too comfortable and wishing to monopolise the space.

Room description and layout

12.44 The design (including finishes) – see Figure 115 – should ensure privacy and a quiet environment.

12.42 This room provides a quiet space for confidential telephone conversations or laptop/deskwork by a single person.

12.45 It should contain power, data and telephone services.

Figure 115 Space requirements for quiet workspace ensuring privacy

Space to withdraw chair from desk

Noticeboard

Desk or desktop

Alternative door location

Minimum 1400 working space required

Optional glazed partition, acoustic and visual privacy to be considered

[HBN 00-03 – PDF page 149]

Staff communication base

Room description and layout

12.59 The security of the base when not manned/out-of- hours may be achieved by either placing it within a total locked zone of the building or by providing a lockable security grille or similar device to enclose the base.

12.46 A staff communication base is a workstation, typically with a split-level counter, intended as a clinical management base within a clinical area.

12.47 It replaces the “nurses base” from previous guidance; changes in working practices means the base will be used by a multidisciplinary team rather than just nurses.

12.60 Care needs to be taken when determining the counter design; high counters can make it difficult for staff and clients to communicate, especially where the client is of short stature, a child, in a wheelchair, or if the client or staff member is hearing impaired. High and particularly wide counters can also create ergonomic risks for staff, particularly short staff.

12.48 It should provide good observation of the clinical area served. Staff emergency call facilities should be provided at the desk.

12.49 A telephone and computer should be provided. Task lighting should be considered.

12.61 A low counter is typically around 720 mm above the floor and is suitable for wheelchair/seated users and children. In some circumstances consideration may be given to allowing both the member of staff and client to sit as it may create a more intimate situation.

12.50 Lamp repeat calls for controlled drugs cupboards (if used) will be located here. An alarm panel may be provided.

12.51 Access to a safe room/space must be provided behind the base to ensure staff safety. This could be access to a safe corridor.

12.62 A high counter, also known as a parcel shelf, may be provided to shield equipment etc from outside view, to provide a convenient writing surface for visitors or staff or to provide an additional safety barrier without the use of intimidating safety glass.

12.52 A local printer and fax machine may be located in a room behind the base or other nearby secure area.

12.53 A space for private discussions should be provided nearby. This may form a discrete part of the base with glass screens or an interview room may be provided for this purpose.

12.63 A high counter designed for direct interaction between staff and clients should not result in excessive reach across the work surface. The recommended height of a high counter is around 1200 mm and it should be designed to permit the location of a flat panel monitor on the work surface below (note: BS 8300 recommend a 1100 mm high counter to support standing users).

12.54 The number of workstations should be based on maximum staff usage at any one time.

12.64 Staff communication bases with both high and low sections are generally recommended.

12.55 Space around the base should ensure free movement of traffic when someone is standing in front of the base.

12.65 The recommended minimum working width for a member of staff at the base is 800 mm per person. A width of 1200 mm per person is generally only required for prolonged use but has been included in the examples for flexibility.

12.56 The layout provided (see Figure 116) illustrates the generic design issues and space requirements for a staff communication base. Actual design requirements will depend upon local requirements.

12.57 The main issues to consider when evaluating the requirements for a staff communication base are:

• the safety of staff at the base and security of the base out-of-hours;

12.66 BS 8300 recommends, and Approved Document M requires, that the minimum width of the low level section of counter is 1500 mm, preferably 1800 mm, to allow for a wheelchair user and attendant on one side or two wheelchair users to face each other diagonally.

• the height and size of the desk, which will relate to its access and use.

12.67 In addition to staff emergency call, power and data services, the following controls and/or indicators may be located at the base as appropriate:

12.58 Staff security may be achieved by providing a vertical or horizontal barrier in front of the base and a safe place behind the base.

[HBN 00-03 – PDF page 150]

12 Generic clinical admin spaces: Open-plan admin areas

• controls for general lighting, heating, medical gas isolation and entry systems;

12.68 For more details of the space requirements for access to the desk for wheelchair users see BS 8300.

• indicator panels for call systems, fire alarm and controlled drugs cupboards.

Figure 116 Space requirement for staff communication base

Optional security grille/enclosure

Optional security grille/ enclosure

Access to staff only area for safety

Optional protective hood, parcel shelf/top counter

approx 1200

ENCLOSED BASE

approx 800

ambulant passing

desk standing

Access to staff only area for safety

Space for two people ambulant/semi-ambulant passing

withdrawing from desk

ambulant passing

Space for bed movement

Space for wheelchair user access

Low-level counter for wheelchair user or children’s access – minimum overall width of low-level section 1500

PART OPEN BASE

Alarm panel

Mobile storage

Access to staff only area for safety

Space behind desk for one person only

OPEN BASE

Space behind desk for wheelchair access

[HBN 00-03 – PDF page 151]

Touchdown base

staff, standing or perching on a stool, does not cause an obstruction.

Room description and layout

12.72 An alarm panel and lamp repeat calls for controlled drugs cupboards (if used) may be located here.

12.69 A touchdown base is intended for accessing and updating electronic patient records and other computer work, adjacent to, but not within, an individual clinical room. It should only be used for short periods of time.

12.73 The computer screen should provide good visibility to the user. Task lighting should be considered.

12.74 The security of information should be considered when the computer is not in use/not manned.

12.70 The touchdown base may consist of a worktop (as shown) or mobile workstation and computer at standing height.

12.75 The base should include a telephone socket.

12.71 A touchdown base should be recessed sufficiently from any circulation routes so that a member of

12.76 The layout provided (see Figure 117) is based on single-person use.

Figure 117 Space requirement for a touchdown base, single-person use

Maximum projection of optional wall- mounted storage

Optional

observation window

into clinical space

Approx 1420, eye level small person

Touchdown base Circulation space varies

Optional stool

Working area length Approx 1750, eye level tall person

Space to stand and work and ro allow passing. 900 preferred if sitting

Space for two people ambulant/ semi-ambulant passing

Space for bed movement

1600 for sitting at touchdown base

[HBN 00-03 – PDF page 152]

12 Generic clinical admin spaces: Open-plan admin areas

Ergonomic drawings

Clinical workstation

12.78 The clinical workstation is intended for accessing and updating patient records within a clinical environment. It should only be used for short periods of time.

12.77 This ergonomic drawing (see Figure 118) shows the space requirements for a clinical workstation.

Figure 118 Space requirements for a clinical workstation

Approximate

Approximate

sitting height

standing height

Chair

standing at

clinical

workstation

workstation

sitting at clinical