Home › Scotland (NHS Scotland Assure / HFS) › HBN 00-03 › Health Building Note 00-03 – 12 Generic clinical admin spaces: Open-plan admin areas (pages 137–144)

HBN 00-03: Health Building Note 00-03 – 12 Generic clinical admin spaces: Open-plan admin areas (pages 137–144)

Core guidance - Clinical and clinical support spaces (HBN 00-03) · PDF pages 137–144 of 166 · Source file: hbn-00-03-oct-2014.pdf
Unofficial text extract. Tables and figures may be incomplete. Authoritative version: official PDF from NHS National Services Scotland.

[HBN 00-03 – PDF page 137]

12 Generic clinical admin spaces: Open-plan admin areas

• space for the workstation;

Admin area: continuous use

Room description and layout

• one interview room (4 places) for every 16 workstations;

12.1 This area is suitable for full-time office-based staff.

• one quiet workspace for every 16 workstations (not included within base standard if eight or fewer workstations);

12.2 The layout provided (see Figure 108) includes eight dedicated workstations.

• one breakout space for every 16 workstations (not included within base standard if eight or fewer workstations);

12.3 Each workstation space includes a lockable filing cabinet and lockable desk-high storage unit for staff personal belongings, for example laptop, mobile phone etc.

12.4 The continuous use administration area as defined here excludes:

• one photocopy/printing room, with multifunctional printer/copier and storage for paper/printing supplies, for every 32 workstations.

• significant clinical or administrative storage space;

12.8 The allowances include access space within the open plan area but exclude external circulation space.

• local printing facilities (as these are not considered appropriate for sustainability reasons).

12.9 The allowance of 6.6 m² is the average figure from the calculations below.

12.5 For sizing continuous use open plan administration areas (with six or more workstations) an allowance of 5 m² per workstation may be used.

12.10 The breakout space is not essential where dedicated workstations are provided but is recommended for flexibility in use.

12.6 In order to function properly, a series of support spaces are recommended where workstations are provided within open plan areas.

12.11 Open-plan areas with their associated support spaces have similar net space requirements per workstation to 2-person offices. However, open- plan areas are considered more flexible and have lower circulation requirements.

12.7 For briefing purposes, open-plan offices with eight or more workstations may be sized at 6.6 m² per workstation. This allows for the following:

[HBN 00-03 – PDF page 138]

12 Generic clinical admin spaces: Open-plan admin areas

Figure 108 Space requirements for eight dedicated workstations, administration area

Possible window

Possible window Notice/ display board

Notice/ display board

Notice/ display board

Possible zone

for engineering

service outlets

S1 S2 S5 S6

D6

D2

Visitor’s chair

Visitor’s chair

D5

D1

F1 F3

F5

F6

F8 F2

F4

F7

D4

Visitor’s chair

Visitor’s chair

Desk space @ 4.5 sq m per desk

D7

D3

S3

S8 S7 S4

Access zone

to desks

Desk space @ 4.5 sq m per desk S = Personal storage D = Desk or desktop F = Filing cabinet

[HBN 00-03 – PDF page 139]

Table 3 Open-plan office sizes

Open-plan office space: 8 workstations

Component spaces Qty Unit area allowance (m²) Total are (m²) Open-plan office

allowance (m²)

Dedicated workstations 5.0 40.0

Photocopy/printing room 6.0 6.0

Breakout space 6.0 0.0

Quiet workspace 5.5 0.0

Interview room 8.0 8.0

Net allowance 54.0 6.8 per workstation

Open-plan office space: 64 dedicated workstations

Component spaces Qty Unit area allowanc (m²) Total area (m²) Open-plan office

allowance (m²)

Dedicated workstations 5.0 320.0

Photocopy/printing room 6.0 12.0

Breakout space 6.0 24.0

Quiet workspace 5.5 22.0

Interview room 8.0 32.0

Net allowance 410.0 6.4 per workstation

Open-plan office space: 8 shared workstations (32 staff)

Component spaces Qty Unit area allowance (m²) Total area (m²) Open-plan office

allowance (m²)

Shared workstations 5.0 40.0

Photocopy/printing room 6.0 6.0

Breakout space 6.0 0.0

Quiet workspace 5.5 0.0

Interview room 8.0 8.0

Net allowance 54.0 6.8 per workstation

Open-plan office space: 60 shared workstations (240 staff)

Component spaces Qty Unit area allowance (m²) Total area (m²) Open-plan office

allowance (m²)

Shared workstations 5.0 300.0

Photocopy/printing room 6.0 12.0

Breakout space 6.0 24.0

Quiet workspace 5.5 22.0

Interview room 8.0 32.0

Net allowance 390.0 6.5 per workstation

[HBN 00-03 – PDF page 140]

12 Generic clinical admin spaces: Open-plan admin areas

Ergonomic drawings

Administration workstation

12.14 Desks should include wire management and equipment should be able to be plugged in at desk height. Task lighting should be considered.

12.12 This ergonomic drawing (see Figure 109) shows the space requirements for an administration workstation.

12.15 The 900 mm space required to withdraw a chair from the desk will increase to 1000 mm for heavy upholstered chairs.

12.13 Office furniture should comply with BS EN 1335- 1.

12.16 Where there is frequent passing behind a desk, the preferred 1500 mm space should be provided. This will also allow for wheelchair access.

Figure 109 Space requirements for an administration workstation

Privacy screen

Minimum 1500 required for wheelchair access

1500 (1200) to obstruction

ambulant passing

Space to sit at desk/approx depth of storage unit

Noticeboard

Mobile under-desk storage

Approximate

width of mobile

storage unit

1400 (1200) – see notes

Filing cabinet or bookcase

Space to withdraw chair from desk

Space for ambulant passing when chair withdrawn

[HBN 00-03 – PDF page 141]

• space for the workstation;

Admin area: shared use

Room description and layout

• one interview room (4 places) for every 16 workstations;

12.17 The layout provided (see Figure 110) includes eight shared workstations.

• one quiet workspace for every 16 workstations (not included within base standard if eight or fewer workstations);

12.18 The layout is based on four people sharing a workstation. There are four dedicated lockable desk-high storage units for each workstation (i.e. one for each person).

• one breakout space for every 16 workstations (not included within base standard if eight or fewer workstations);

• one photocopy/printing room for every 32 workstations.

12.19 The provision of DDI number access to phone systems may help to enable the shared use of workstations.

12.23 The allowances include access space within the open plan area but exclude external circulation space.

12.20 For sizing shared open plan administration areas (with six or more workstations) an allowance of 5 m² per workstation may be used.

12.24 The allowance of 6.6 m² is the average figure from the calculations below.

12.21 In order to function properly, a series of support spaces are recommended where workstations are provided within open plan areas.

12.22 For briefing purposes, open plan offices with eight or more workstations may be sized at 6.6 m² per workstation. This allows for the following:

12.25 Open-plan areas with their associated support spaces have similar net space requirements per workstation to 2-person offices. However, open plan areas are considered more flexible and have lower circulation requirements.

[HBN 00-03 – PDF page 142]

12 Generic clinical admin spaces: Open-plan admin areas

Figure 110 Admin area: shared use: 8 workstations

Possible window

Possible window Notice/ display board

Notice/ display board

Notice/ display board

Possible zone

for engineering

service outlets

S3

S1 S1 S1 S1 S3

S4

S4

D2

D6

D5

D1

S3

S3

S4

S4

S2

S2

S2

S2

S2

S2

S2

S2

S3

S3

S4

D4

S4

D8

Desk space @ 4.5 sq m per desk

D7

D3

S3

S3

S1

S4 S1 S1 S1

S4

Access zone

to desks

Desk space @ 4.5 sq m per desk

S = Personal storage D = Desk or desktop

[HBN 00-03 – PDF page 143]

Table 4 Open-plan office sizes

Open-plan office space: 8 workstations

Component spaces Qty Unit area allowance Total area Open-plan office allowance

Dedicated workstations 5.0 40.0

Photocopy/printing room 6.0 6.0

Breakout space 6.0 0.0

Quiet workspace 5.5 0.0

Interview room 8.0 8.0

Net allowance 54.0 6.8 per workstation

Open-plan office space: 64 dedicated workstations

Component spaces Qty Unit area allowance Total area Open-plan office allowance

Dedicated workstations 5.0 320.0

Photocopy/printing room 6.0 12.0

Breakout space 6.0 24.0

Quiet workspace 5.5 22.0

Interview room 8.0 32.0

Net allowance 410.0 6.4 per workstation

Open-plan office space: 8 shared workstations (32 staff)

Component spaces Qty Unit area allowance Total area Open-plan office allowance

Shared workstations 5.0 40.0

Photocopy/printing room 6.0 6.0

Breakout space 6.0 0.0

Quiet workspace 5.5 0.0

Interview room 8.0 8.0

Net allowance 54.0 6.8 per workstation

Open-plan office space: 60 shared workstations (240 staff)

Component spaces Qty Unit area allowance Total area Open-plan office allowance

Shared workstations 5.0 300.0

Photocopy/printing room 6.0 12.0

Breakout space 6.0 24.0

Quiet workspace 5.5 22.0

Interview room 8.0 32.0

Net allowance 390.0 6.5 per workstation

[HBN 00-03 – PDF page 144]

12 Generic clinical admin spaces: Open-plan admin areas

Ergonomic drawings

Administration workstation

12.28 Desks should include wire management and equipment should be able to be plugged in at desk height. Task lighting should be considered.

12.26 This ergonomic drawing (see Figure 111) shows the space requirements for an administration workstation.

12.29 The 900 mm space required to withdraw a chair from the desk will increase to 1000 mm for heavy upholstered chairs.

12.27 Office furniture should comply with BS EN 1335- 1.

12.30 Where there is frequent passing behind a desk, the preferred 1500 mm space should be provided. This will also allow for wheelchair access.

Figure 111 Space requirements for an administration workstation

Privacy screen

Minimum 1500 required for wheelchair access

1500 (1200) to obstruction

ambulant passing

Space to sit at desk/approx depth of storage unit

Noticeboard

Mobile under-desk storage

Approximate

width of mobile

storage unit

1400 (1200) – see notes

Filing cabinet or bookcase

Space to withdraw chair from desk

Space for ambulant passing when chair withdrawn