Home › England (NHS England estates) › HTM 05-02 › Appendix K: References

HTM 05-02: Appendix K: References

Firecode - Guidance in support of functional provisions (Fire safety in the design of healthcare premises) · PDF pages 105–109 of 112 · Source file: HTM_05-02_2015.pdf
Unofficial text extract. Tables and figures may be incomplete. Authoritative version: official PDF from NHS England.

[HTM 05-02 – PDF page 105]

Appendix K: References

Acts and Regulations

Building Regulations 2010. SI 2010 No 2214. HMSO, 2010.

EUROPEAN PARLIAMENT AND OF THE COUNCIL of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC. Published in the Official Journal L88, 04 April 2011.”

Firecode publications

Building Regulations 2010: Approved Document B: Fire Safety – Volume 2. Department for Communities and Local Government, 2006 edition (incorporating 2007, 2010 and 2013 ammendments).

Health Technical Memorandum 05-01: Managing healthcare fire safety. Second edition. Department of Health, 2013.

Building Regulations 2000: Approved Document F: Ventilation. Department for Communities and Local Government, 2010.

Health Technical Memorandum 05-03: Part A. General fire safety. Department of Health, 2013.

Building Regulations 2000: Approved Document K: Protection from falling, collision and impact. Department for Communities and Local Government, 2013.

Health Technical Memorandum 05-03: Part B. Fire detection and alarm systems. The Stationery Office, 2006.

Regulatory Reform (Fire Safety) Order 2005. SI 2005 No 541. HMSO, 2005. http://www.opsi.gov.uk/si/si2005/20051541.htm

Health Technical Memorandum 05-03: Part D. Commercial enterprises on healthcare premises. Second edition. Department of Health, 2013.

European legislation

Health Technical Memorandum 05-03: Part E. Escape bed lifts. The Stationery Office, 2006.

Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products. Official Journal of the European Communities. L 40, 11.02.1989, p 12.

Health Technical Memorandum 05-03: Part F. The prevention and control of arson in NHS healthcare premises. Department of Health, 2013.

Construction Products Regulations: “REGULATION (EU) No 305/2011 OF THE

[HTM 05-02 – PDF page 106]

relevant requirements of these recommendations.

Health Technical Memorandum 05-03: Part G. Laboratories on healthcare premises. The Stationery Office, 2006.

BS 476-4:1970. Fire tests on building materials and structures. Non-combustibility test for materials. British Standards Institution, 1970.

Health Technical Memorandum 05-03: Part H. Reducing false alarms in healthcare premises. Department of Health, 2013.

BS 476-6:1989+a1:2009. Fire tests on building materials and structures. Method of test for fire propagation for products. British Standards Institution, 2009.

Health Technical Memorandum 05-03: Part J. Guidance on fire engineering of healthcare premises. The Stationery Office. 2008.

BS 476-7:1997. Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products. British Standards Institution, 1997.

Health Technical Memorandum 05-03: Part K. Guidance on fire risk assessments in complex healthcare premises. Department of Health, 2013.

BS 476-11:1982. Fire tests on building materials and structures. Method for assessing the heat emission from building materials. British Standards Institution, 1982.

Health Technical Memorandum 05-03: Part L. NHS Fire statistics 1994/5–2004/5. The Stationery Office. 2007.

Health Building Notes

BS 476-20:1987. Fire tests on building materials and structures. Method for determination of the fire resistance of elements of construction (general principles). British Standards Institution, 1987.

Health Building Note 00-04: Circulation and communication spaces. Department of Health, 2013.

Health Technical Memoranda

BS 476-21:1987. Fire tests on building materials and structures. Methods for determination of the fire resistance of loadbearing elements of construction. British Standards Institution, 1987.

Health Technical Memorandum 02-01: Medical gas pipeline systems. The Stationery Office, 2006.

Health Technical Memorandum 03-01: Specialised ventilation for healthcare premises. The Stationery Office, 2007.

BS 476-22:1987. Fire tests on building materials and structures. Methods for determination of the fire resistance of non- loadbearing elements of construction. British Standards Institution, 1987.

Health Technical Memorandum 06-01: Electrical services: supply and distribution. The Stationery Office, 2007.

BS 476-23:1987. Fire tests on building materials and structures. Methods for determination of the contribution of components to the fire resistance of a structure. British Standards Institution, 1987.

Health Technical Memorandum 08-02: Lifts. Department of Health, 2010.

British and European Standards

BS 476-24:1987, ISO 6944:1985. Fire tests on building materials and structures. Method for determination of the fire resistance of ventilation ducts. British Standards Institution, 1987.

The latest version of any standard should be used, provided that it continues to address the

[HTM 05-02 – PDF page 107]

Appendix K: References

BS 5588-8:1999. Fire precautions in the design, construction and use of buildings. Code of practice for means of escape for disabled people. British Standards Institution, 1999.

BS 476-31.1:1983. Fire tests on building materials and structures. Methods for measuring smoke penetration through doorsets and shutter assemblies. Method of measurement under ambient temperature conditions. British Standards Institution, 1983.

BS 5588-9:1999. Fire precautions in the design, construction and use of buildings. Code of practice for ventilation and air conditioning ductwork. British Standards Institution, 1999.

BS 1635:1990. Recommendations for graphic symbols and abbreviations for fire protection drawings. British Standards Institution, 1990.

BS 3251:1976. Specification. Indicator plates for fire hydrants and emergency water supplies. British Standards Institution, 1976.

BS 5588-12:2004. Fire precautions in the design, construction and use of buildings. Managing fire safety. British Standards Institution, 2004.

BS 5266-1:2011. Emergency lighting. Code of practice for the emergency lighting of premises. British Standards Institution, 2011.

BS 5839-1:2002+A2:2008. Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance. British Standards Institution, 2008.

BS 5306-1:2006. Code of practice for fire extinguishing installations and equipment on premises. Hose reels and foam inlets. British Standards Institution, 2006.

BS 5839-3:1988. Fire detection and alarm systems for buildings. Specification for automatic release mechanisms for certain fire protection equipment. British Standards Institution, 1988.

BS EN 12845:2004+A2:2009. Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance. British Standards Institution, 2009.

BS 5867-2:2008. Fabrics for curtains, drapes and window blinds. Flammabililty requirements. Specification. British Standards Institution, 2008.

BS 5306-3:2009. Fire extinguishing installations and equipment on premises. Commissioning and maintenance of portable fire extinguishers. Code of practice. British Standards Institution, 2009.

BS EN 12600:2002. Glass in building. Pendulum test. Impact test method and classification for flat glass. British Standards Institution, 2002.

BS 5306-8:2012. Fire extinguishing installations and equipment on premises. Selection and positioning of portable fire extinguishers. Code of practice. British Standards Institution, 2012.

BS 7863:2009. Recommendations for colour coding to indicate the extinguishing media contained in portable fire extinguishers. British Standards Institution, 2009.

BS 5588-5:2004. Fire precautions in the design, construction and use of buildings. Access and facilities for fire-fighting. British Standards Institution, 2004.

BS 9990:2006. Code of practice for non- automatic fire-fighting systems in buildings. British Standards Institution, 2006.

BS 5588-7:1997. Fire precautions in the design, construction and use of buildings. Code of practice for the incorporation of atria in buildings. British Standards Institution, 1997.

BS EN 3-8:2006. Portable fire extinguishers. Additional requirements to EN 3-7 for the construction, resistance to pressure and mechanical tests for extinguishers with a

[HTM 05-02 – PDF page 108]

maximum allowable pressure equal to or lower than 30 bar. British Standards Institution, 2006.

BS EN 1366-2:1999. Fire resistance tests for service installations. Fire dampers. British Standards Institution, 1999.

BS EN 3-9:2006. Portable fire extinguishers. Additional requirements to EN 3-7 for pressure resistance of CO2 extinguishers. British Standards Institution, 2006.

BS EN 1634-1:2014. Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware. Fire resistance test for door and shutter assemblies and openable windows. British Standards Institution, 2014.

BS EN 3-10:2009. Portable fire extinguishers. Provisions for evaluating the conformity of a portable fire extinguisher to EN 3-7. British Standards Institution, 2009.

BS EN 1634-3:2004. Fire resistance tests for door and shutter assemblies. Smoke control doors and shutters. British Standards Institution, 2004.

BS EN 3-7:2004+A1:2007. Portable fire extinguishers. Characteristics, performance requirements and test methods. British Standards Institution, 2007.

BS EN 54. Fire detection and fire alarm systems. (12 parts). British Standards Institution.

BS EN 12101-3:2002. Smoke and heat control systems. Specification for powered smoke and heat exhaust ventilators. British Standards Institution, 2002.

BS EN 81-1:1998+A3:2009. Safety rules for the construction and installation of lifts. Electric lifts. British Standards Institution, 2009.

BS EN 12101-6:2005. Smoke and heat control systems. Specification for pressure differential systems. Kits. British Standards Institution, 2005.

BS EN 81-2:1998+A3:2009. Safety rules for the construction and installation of lifts. Hydraulic lifts. British Standards Institution, 2009.

BS EN 12600:2002. Glass in building. Pendulum test. Impact test method and classification for flat glass. British Standards Institution, 2002.

BS EN 81-58:2003. Safety rules for the construction and installation of lifts. Examination and tests. Landing doors fire resistance test. British Standards Institution, 2003.

BS EN 12845:2004+A2:2009. Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance. British Standards Institution, 2009.

BS EN 81-72:2003. Safety rules for the construction and installation of lifts. Particular applications for passenger and goods passenger lifts. Firefighters’ lifts. British Standards Institution, 2003.

BS EN 13501-3:2005+A1:2009. Fire classification of construction products and building elements. Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers. British Standards Institution, 2009.

BS EN 1154:1997. Building hardware. Controlled door closing devices. Requirements and test methods. British Standards Institution, 1997.

BS 2782-0:2011. Methods of testing plastic. Part 0: Introduction. British Standards Institution, 2011.

BS EN 1155:1997. Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods. British Standards Institution, 1997.

BS ISO 10294-5:2005. Fire-resistance tests. Fire dampers for air distribution systems.

[HTM 05-02 – PDF page 109]

Appendix K: References

Intumescent fire dampers. British Standards Institution, 2005.

Other publications

Chartered Institution of Building Services Engineers (CIBSE). Lighting Guide 02: Hospitals and Health Care Buildings (Society of Light and Lighting SLL LG2). CIBSE, 2008.

Building Research Establishment. BRE Report 187: External fire spread: building separation and boundary distances. BREPress, 1991.

Fire Protection Association. LPC rules for automatic sprinkler installations. Fire Protection Association, 2009 (includes technical bulletins). http://www.thefpa.co.uk

Building Research Establishment. BRE Digest 208: Increasing the fire resistance of existing timber floors. BREPress, 1988.

Health & Safety Executive. Fire safety in construction. HSG168. HSE Books, 2010. http://www.hse.gov.uk/pubns/books/hsg168. htm

Building Research Establishment. BD 2466: Guidance on emergency use of lifts or escalators and fire and rescue service operation. Department for Communities and Local Government, 2009.

International Association for Cold Storage Construction (IACSC) (European Division). Design, construction, specification and fire management of insulated envelopes for temperature controlled environments. IACSC, 1999).

Building Research Establishment. BRE Report 368: Design methodologies for smoke and heat exhaust ventilation. BREPress, 1999.