HBN 00-04: 2 General design and functional considerations
[HBN 00-04 – PDF page 14]
2 General design and functional considerations
Statutory and other requirements
(2013) and BS 8300:2009+A1:2010 is recommended.
2.7 Floor colours should contrast visually with wall colours. Monochromatic colour schemes should be avoided.
2.8 Visual contrast may also be used to highlight specific features, for example lifts, stairs, doors, light switches and litter bins.
2.9 Contrasting handrails/crash rails may be fitted to act as navigation tools.
2.10 For detailed information on the use of colour and visual contrast, see:
• T21027: Dulux Trade Colour & Contrast CD;
2.1 This guidance has been prepared following a review of Health Building Note 40 and relevant minimum standards/recommendations in Approved Document M (2013) of the Building Regulations and BS 8300:2009+A1:2010. Building Regulations are made for specific purposes, primarily the health and safety, welfare and convenience of people and for energy conservation. Standards and other technical specifications may provide relevant guidance to the extent that they relate to these considerations. However, they may also address other aspects of performance or matters which, although they relate to health and safety etc, are not covered by the Building Regulations.
• Approved Document M (2103) and BS 8300: 2009+A1:2010;
• ‘Colour, contrast and perception – Design guidance for internal built environments’ (Reading University);
• ‘Building sight’ (Royal National Institute for the Blind);
2.2 Where this guidance exceeds or specifically varies from BS 8300:2009+A1:2010 or Approved Document M (2013), this guidance is intended to supersede these standards for healthcare premises. See Appendix 2 for details of how this guidance differs from the guidance provided by Approved Document M (2013) and BS 8300:2009+A1:2010.
• ‘Lighting and colour for hospital design’ (Dalke et al).
2.3 See Appendix 3 for a list of some of the main statutory requirements that relate to circulation and communication spaces.
Wall and floor finishes
Wayfinding
2.11 Highly-patterned walls and floors should be avoided.
2.4 For information on signage see ‘Wayfinding: effective wayfinding and signing systems guidance for healthcare facilities’.
2.12 Floor and wall surfaces should minimise light reflection.
Visual and colour contrast
2.13 Floor surfaces should be slip-resistant (whether wet or dry). See ‘Safer surfaces to walk on – reducing the risk of slipping’ (CIRIA) for further guidance on appropriate floor finishes.
2.5 Visual contrast is as important as colour contrast, as some people with visual impairments confuse different colours of similar tone.
2.14 For ease of mobility, floors and floor finishes should be firm. The use of soft coverings, such as thick carpet, should be avoided.
2.6 Approved Document M (2013) and BS 8300:2009 +A1:2010 define visual contrast by referring to a difference in light reflectance values (LRV). Where this document refers to visual contrast, a difference in LRV as defined in Approved Document M
[HBN 00-04 – PDF page 15]
control advice, should also influence the choice of finishes.
2.15 Junctions between different flooring materials should be carefully detailed so that they do not constitute an obstacle or tripping hazard.
Access and security
2.16 All finishes and junctions between finishes (for example between walls and floors) should be easily cleanable and not support the propagation of bacteria etc.
2.18 The trust’s nominated local security management specialist (LSMS) should be consulted for advice and guidance on the implementation of security measures to ensure the safety of staff and security of premises.
2.19 Access controls should be installed to all non-public areas.
2.17 See Health Building Note 00-10 Part A: ‘Flooring’ and Part B: ‘Walls and Ceilings’ for details of recommended finishes. See also ‘The Healthcare Cleaning Manual’ (DH) for details of best practice cleaning methods, which, along with infection