HBN 00-03: Health Building Note 00-03 – 3 Generic clinical spaces: Consulting, examination and interview spaces (pages 29–36)
[HBN 00-03 – PDF page 29]
Figure 11 Space requirements for standing use of a clinical wash-hand basin
Clinical wash-hand basin
assembly
Space to use basin at high level, ie above 600 mm from floor level
3.38 These ergonomic drawings (see Figure 11) show the space requirements for standing use of a clinical wash-hand basin assembly. For seated use, the basin will need to be lowered.
3.39 The basin should be fitted with non- touch taps.
Soap dispenser Hand cream dispenser Optional scrub solution dispenser Paper towel dispenser
Glove & apron dispenser
high level
Space to use basin at
3.40 The recommended fixing height of a lever tap on a clinical wash-hand basin is 1095 mm. Where a lever tap is used, the fixing height of the dispensers should be chosen to reduce any possible conflicts in use.
Space to use
from floor level
ie up to 600 mm
basin at low level,
Space to use basin at low level, ie up to 600 mm from floor level Elevation (showing sensor tap)
Concealed waste
~120 service duct
Minimum distance to side wall
Paper towel dispenser
3.41 The illustrated clinical wash-hand basin projects 400 mm from the back panel or wall. However, clinical wash-hand basins may vary from 350 to 500 mm projection. Where basins deeper than 400 mm are used, the impact on/from other components and/or activities undertaken within any space should be considered when evaluating any room layout.
(50) Minimum clearance between paper towel dispenser and duct
Projecting concealed services duct
3.42 The glove and apron dispenser illustrated is a combined unit; this is considered the most compact solution although separate units may also be used. Even the most compact unit cannot practically be located within comfortable reach of the basin; it should, however, be conveniently located within the room.
Concealed waste
Minimum distance to side wall
~120 service duct
3.43 The ergonomic advice for the height of horizontal elbow operated lever taps is based on the following data:
Space to use
from floor level
Space to use
ie up to 600 mm
basin at low level,
from floor level
ie above 600 mm
basin at high level,
passing
ambulant
“Elbow height for shod, slightly bent posture (as when leaning forward) for 50%ile UK male = 1134 mm, for female 1049 mm. 1090 mm is considered the best compromise for an elbow height for both male and female use. The ergonomic advice for the height of a lever tap is 75 mm below elbow height giving a figure height of approx 1015 mm.”
3.44 Lever taps are not illustrated.
Comfortable reach to side of basin
Flush concealed services duct
3.45 For detailed information on basins, see Health Building Note 00-10 Part C – ‘Sanitary assemblies’.
[HBN 00-03 – PDF page 30]
3 Generic clinical spaces: Consulting, examination and interview spaces
Couch: double-sided access
3.48 Ceiling-mounted examination lights should be provided where double-sided couch access is required.
3.47 These ergonomic drawings (see Figure 12) show the space requirements for double-sided access to a three-section couch. The overall general space requirements for a three-section couch are the same as for a two-section couch.
Figure 12 Space requirements for double-sided access to a three-section couch
Approximate
Suction bottle bracket to be below patient’s chest
Engineering services outlets requirements
see HTM 02-01 and HTM 08-03
height range of couch
Space for changing
examination/
examination/
treatment
treatment
Couch with paper roll attached
Ceiling- mounted examination light
examination/treatment
[HBN 00-03 – PDF page 31]
Treatment chairs (various): double-sided access
use of the various methods is subject to local clinical and/or patient/ client preferences.
3.49 These ergonomic drawings (see Figure 13) show the space requirements for double-sided access to a variety of treatment chairs.
3.52 The podiatry treatment chair incorporates separate leg supports, which may be adjusted independently of one another.
3.50 The reclining treatment/therapy chair provides the most flexible option for general examinations and treatments.
3.53 The activity space for the podiatry treatment chair assumes the examination light is attached to the podiatry trolley. The illustrated chair is mobile. Floor-mounted chairs are also available although these may reduce flexibility in room use.
3.51 The reclining gynaecology chair may be used for general examinations and treatments or female internal examinations. A variety of attachments are available to assist internal examinations of females including stirrups, leg supports or footrests. The
Figure 13 Space requirements for double-sided access to a variety of treatment chairs
changing
Space for changing
examination/ treatment
Reclining gynaecology chair
Reclining treatment chair
Ceiling- mounted examination light
reclining position
reclining position
Approx length of chair in
Approx length of chair in
Stool
approx 1050
Stool
treatment
access
examination/
access
Space for changing
access side of treatment chair
access
Podiatry treatment chair
reclining position
Approx length of chair in
chair in sitting position
Approximate length of
Stool
examination
access
for treatment/
Approximate space
[HBN 00-03 – PDF page 32]
3 Generic clinical spaces: Consulting, examination and interview spaces
Dressing and undressing: ambulant
3.55 An identical space provision is suitable for semi- ambulant users though it should be located adjacent to a seating area.
3.54 These ergonomic drawings (see Figure 14) show the space requirements for ambulant dressing and undressing.
Figure 14 Space requirements for ambulant dressing and undressing
Maximum height
of permissible
low-level
obstructions
Space for full arm movements
when dressing and undressing
Space for arm movements when dressing and undressing
Space at floor/low level for dressing and undressing
Space at floor/low
level for dressing
and undressing
Space for arm movements
when dressing and undressing
[HBN 00-03 – PDF page 33]
Consulting/examination room: single- sided couch access
Room description and layout
3.56 This room is intended as a flexible space for consultations and examinations for use by a wide range of specialties.
3.60 The layout shows the clinical wash-hand basin within the curtained examination area. However, its location should be subject to local policy and infection control advice. It must be easily accessible from both the consultation and examination areas. The curtain should be located to prevent it becoming contaminated from use of the clinical wash-hand basin.
3.57 The following procedures may take place in this room:
3.61 Piped medical gases are generally not required. In emergency situations it is anticipated that bottled oxygen and mobile suction equipment will be readily available.
• non-invasive procedures, that is, procedures that do not break the skin, for example changing a dressing;
• minimally invasive procedures, that is, procedures that break or puncture the skin, for example injections, taking blood etc.
3.62 The room layout provided mean the patient/client will be positioned between the practitioner and the door during consultation. Consideration may be given to altering the layout to position the practitioner between the patient/client and the door for staff safety.
3.58 The room layout provided (see Figure 15) includes a two-section couch.
3.59 Where it is not necessary to access both sides of the couch, the single-sided room layout may be used but to maximise flexibility and adaptability double- sided couch access is generally recommended.
3.63 The layout has the disadvantage of the consultation area being located on the inside wall (that is, generally away from natural light) and the examination area being located on the outside wall (that is, requiring privacy control due to the likely proximity of a window).
Figure 15 Consulting/examination room, single-sided couch access
Sack holder
Wall-mounted examination light
Couch with paper roll attached
Clinical wash-hand basin
Supplies trolley
Sack holder
Paper towel dispenser
Glove and apron dispenser
Chair
Consultation workstation
Chair
Engineering services outlet zone Engineering services outlet zone
Engineering services outlet zone
[HBN 00-03 – PDF page 34]
3 Generic clinical spaces: Consulting, examination and interview spaces
Ergonomic drawings
3.66 It should be possible to rotate the computer monitor to allow the patient/client to view it.
Consultation workstation
3.67 The consultation desk should be positioned so that:
• the practitioner can acknowledge a patient/ client on entry to the room;
• the practitioner is not be silhouetted against a window when in consultation with the patient/ client.
3.64 This ergonomic drawing (see Figure 16) shows a nominal space requirement for a consultation workstation. The actual space requirement will depend upon the design and location of the chairs and the design of the desk. The illustrated desk is the recommended minimum dimension for using a flat screen computer.
3.68 A small lockable drawer should be available to store prescription pads if electronic prescriptions are not being used.
3.69 A small local printer may be provided.
3.65 The activity space is based on the practitioner sitting at the desk with the patient/client seated diagonally opposite. The desk should not be located between the practitioner and patient/client.
Figure 16 Nominal space requirement for a consultation workstation
Space for wheelchair access/withdrawal
Space to withdraw
chair from desk
withdrawn
Space for occupied upright chair with person’s legs extended, (1050) for legs
Chair
Consultation
workstation
Chair
chair from desk
Space to withdraw
Chair
Space for wheelchair access/withdrawal
upright chair
Space for occupied
Space for occupied
upright chair
[HBN 00-03 – PDF page 35]
Figure 17 Space requirements for standing use of a clinical wash-hand basin
Clinical wash-hand basin
assembly
Space to use basin at high level, ie above 600 mm from floor level
3.70 These ergonomic drawings (see Figure 17) show the space requirements for standing use of a clinical wash-hand basin assembly. For seated use, the basin will need to be lowered.
3.71 The basin should be fitted with non- touch taps.
Soap dispenser Hand cream dispenser Optional scrub solution dispenser Paper towel dispenser
Glove & apron dispenser
high level
Space to use basin at
3.72 The recommended fixing height of a lever tap on a clinical wash-hand basin is 1095 mm. Where a lever tap is used, the fixing height of the dispensers should be chosen to reduce any possible conflicts in use.
Space to use
from floor level
ie up to 600 mm
basin at low level,
Space to use basin at low level, ie up to 600 mm from floor level Elevation (showing sensor tap)
Concealed waste
~120 service duct
Minimum distance to side wall
Paper towel dispenser
3.73 The illustrated clinical wash-hand basin projects 400 mm from the back panel or wall. However, clinical wash-hand basins may vary from 350 to 500 mm projection. Where basins deeper than 400 mm are used, the impact on/from other components and/or activities undertaken within any space should be considered when evaluating any room layout.
(50) Minimum clearance between paper towel dispenser and duct
Projecting concealed services duct
3.74 The glove and apron dispenser illustrated is a combined unit; this is considered the most compact solution although separate units may also be used. Even the most compact unit cannot practically be located within comfortable reach of the basin; it should, however, be conveniently located within the room.
Concealed waste
Minimum distance to side wall
~120 service duct
3.75 The ergonomic advice for the height of horizontal elbow operated lever taps is based on the following data:
Space to use
from floor level
Space to use
ie up to 600 mm
basin at low level,
from floor level
ie above 600 mm
basin at high level,
passing
ambulant
“Elbow height for shod, slightly bent posture (as when leaning forward) for 50%ile UK male = 1134 mm, for female 1049 mm. 1090 mm is considered the best compromise for an elbow height for both male and female use. The ergonomic advice for the height of a lever tap is 75 mm below elbow height giving a figure height of approx 1015 mm.”
3.76 Lever taps are not illustrated.
Comfortable reach to side of basin
Flush concealed services duct
3.77 For detailed information on basins, see Health Building Note 00-10 Part C – ‘Sanitary assemblies’.
[HBN 00-03 – PDF page 36]
3 Generic clinical spaces: Consulting, examination and interview spaces
Couch: single-sided access
3.79 Wall-mounted examination lights should be provided where single-sided couch access is required. The light may be mounted on a horizontal rail to enable its position to be altered in the horizontal plane.
3.78 This ergonomic drawing (see Figure 18) shows the space requirements for single-sided access to a couch. It illustrates a two-section couch simply as the most likely scenario. The generic access space is believed to be the same for other types of couch.
Figure 18 Space requirements for single-sided access to a couch
height range
Approx adjustable
Engineering services outlets requirements
see HTM 02-01 and HTM 08-03
examination/ treatment
Couch with paper roll attached
Wall- mounted examination light
examination/
treatment