HTM 03-01 A: Abbreviations used in this document
[HTM 03-01 A – PDF page 211]
Abbreviations used in this document
Abbreviations used in this document
EPA Efficiency particulate air filter (E10 to E12)
ac/h Air changes per hour
ErP Energy related products
ACDP* Advisory Committee on Dangerous Pathogens*
ACOP Approved Code of Practice
EU GGMP European Guide to Good Manufacturing Process (pharmacy)
AE(V) Authorising Engineer (ventilation)
AGP Aerosol-generating procedure
GRP Glass reinforced polymer
AHU Air handling unit
AP(V) Authorised Person (ventilation)
HBN Health Building Note
BESA Building Engineering Services Association
HEPA High efficiency particulate air filter (H13 to H14)
BIM Building Information Model
HIS Healthcare Infection Society
BMS Building Management System
HTM Health Technical Memoranda
BEMS Building Energy Management System
BS EN British Standard European Number
IAP Inspection, assembly and packing (room)
ISO International Standards Organisation
BSRIA Building Services Research and Information Association
CCA Critical care area (Level 2 & 3 care)
Level 0 care
Patients whose needs can be met through normal ward care in an acute hospital
cfu Colony forming unit
Level 1 care
CIBSE Chartered Institution of Building Services Engineers
Patients at risk of their condition deteriorating, or recently relocated from higher levels of care, whose needs can be met through normal ward care with additional advice and support from the critical care team.
COSHH Control of Substances Hazardous To Health
CP(V) Competent Person (ventilation)
Level 2 care
CT Computed tomography (imaging)
Patients requiring more detailed observation or intervention, including support for a single failing organ system or post-operative care and those ‘stepping down’ from higher levels of care.
DIPC Director of Infection Prevention and Control
Level 3 care
DOP Dispersed oil particles
DX Direct expansion (refrigeration cycle)
Patients requiring advanced respiratory support alone or monitoring and support for two or more organ systems. This level includes all complex patients requiring support for multi-organ failure.
LEV Local exhaust ventilation
EC Electronicaly commutated (fan)
LSAPC Light scattering airborne particle counter
[HTM 03-01 A – PDF page 212]
MDR-TB Multi-drug-resistant tuberculosis
ULPA Ultra low particulate air filter (U15 to U17)
MRI Magnetic resonance imaging
UV Ultraviolet
NICU Neonate intensive care unit
VAV Variable air volume
PFI Private Finance Initiative
VCD Volume control damper
VSG Ventilation Safety Group
PPVL Positive pressure ventilated lobby (isolation room)
PVC Polyvinyl chloride
WEL Workplace exposure limit
RH Relative humidity
Symbols used
ºC(db) Degrees centigrade (Dry bulb) temperature
SCBU Special care baby unit
K Kelvin (temperature difference)
% RH Percentage relative humidity
SPATA The Swimming Pool and Allied Trades Association
L/s Litres per second
SVHSoc Specialised Ventilation for Healthcare Society
µm Micrometres, microns
TB Tuberculosis
ePM1, 2.5, Particle size in micrometres
TCP Theatre control panel
≥ Equal to or greater than
UCV Ultra clean ventilation
* ACDP Containment levels
Category 1 biohazard: a biological agent unlikely to cause human disease
Category 2 biohazard: a biological agent that can cause human disease and may be a hazard to employees; it is unlikely to spread to the community and there is usually effective prophylaxis or effective treatment available.
Category 3 biohazard: a biological agent that can cause severe human disease and presents a serious hazard to employees; it may present a risk of spread to the community, but there is usually effective treatment or prophylaxis available.
Category 4 biohazard: a biological agent that causes severe human disease and is a serious hazard to employees; it is likely to spread to the community and there is usually no effective prophylaxis or treatment available.
[HTM 03-01 A – PDF page 213]
NHS England and NHS Improvement Skipton House 80 London Road London SE1 6LH
This publication can be made available in a number of other formats on request.
© NHS England and NHS Improvement 2021 Publication approval reference: PAR38